EPS 100 Graphite

  • Standard plate size: 1000 x 500mm
  • Plate area: 0.5 m2
  • Nominal thickness: 10-350 mm
  • Thermal conductivity: λ = 0.030 W/mK
  • Flexural strength: BS 150 ≥ 150 kPa
  • Compressive stress at a deformation of 10%: CS (10)100 ≥ 100 kPa
  • Tensile strength: TR150 ≥ 150 kPa

Thermal insulation of buildings. Thermal insulation boards for ventilated facades and ETICS system facades (thermal insulation systems on the outside of buildings), spaces with medium static load, roof insulation, under leveling cement.

EPS – EN 13163 – T(1)- L(2) – W(1)- Sb(1)- P(3)- BS150- CS(10)100- DS(N)2-DLT(1)5-TR150- WL(T)3– WD(V)1;

gray panels;

Calculate your consumption

DOWNLOADABLE MATERIALS

Technical sheet EPS 100 Graphite

Declaration of Performance EPS 100 Graphite Sfântu Gheorghe

Declaration of Performance EPS 100 Graphite Chișoda

Declaration of Performance EPS 100 Grafitat Cluj

Declaration of Performance EPS 100 Graphite Bragadiru

EPS Hirsch Safety Data Sheet

Leader in insulation